Memmert appliances with the Perfect controller class are equipped by default with an internal card reader. Three different chip cards guarantee additional safety during sterilisation, greater protection from manipulation as well as higher process safety and more extensive options for programming and documentation through storing repeatable temperature profiles.

The MEMoryCard XL: more process safety

Each Memmert appliance of the Perfect class comes as standard with a chip card on which temperature profiles can be stored and logged. On the MEMoryCard, a temperature profile file with up to 40 ramps can be stored and re-used later as often as you want. This helps to support process safety, as well as optimised use of personnel in the laboratory. While the programme is running, the actual values are automatically logged on the card and can be displayed and archived in a data processing system via the device interface or an external card reader.

The User-ID-card: greater protection from manipulation

Each User- ID- card (optional) is unique due to the 128-bit encryption in conjunction with the equipment serial number, and an individual personal identification number, and prevents undesired manipulation by third parties. The menu operation on the Memmert appliance is only released when this personalised chip card is inserted into the card reader. If the appliance is used by several people, a separate User- ID- Card may be purchased for each user, of course.

The STERICard: more safety during sterilisation

For the incubator of the INP Perfect class, for the INCO CO2 incubator and for the HCP humidity chamber, a chip card for absolutely safe sterilisation is included in the delivery. This guarantees safe and fully automatic sterilisation (and not only disinfection) of the interior. For safety reasons, this function can only be started with the STERICard, and is used not for the sterilisation of loads, but exclusively for the sterilisation of the interior. During the sterilisation procedure, menu operation of the appliance is suspended, so that no accidental reprogramming is possible.

Bookmark and Share

HTML Link:

BBCode Link:

To copy the link above, just click on the input box, right click and copy

 Send to a friend Printable version
 
 
 
Random »
Back to top
Back to top

PT. PROLABMAS MURNI SWADAYA
Sentra Niaga Puri Indah Blok T3-10
Jakarta 11610 - Indonesia
Telp: +62 (21) 581 8000, 581 9000
Fax: +62 (21) 581 6999

© 2010 - 2018 Alat Lab | Alat Laboratorium
Developed by: DuaCe.com