Model 1088 Rotary TOC Autosampler

Model 1088 Rotary TOC Autosampler

 

Features


Automates introduction of 88 samples to the Aurora 1030 TOC Analyzer
Configurable for pre-acidication and sparging of sample TIC content within the autosampler to reduce TOC analysis time
Performs programmable rinse steps via an integral wash station to clean the sampling needle and prevent cross-contamination
Magnetic stirring ensures insoluble and particulated samples are homogeneous for accurate results
Fits directly under the Aurora 1030 TOC Analyzer to minimize laboratory benchspace requirements

Supports sampling from open vials and septum piercing of sealed vials

 

Description


The 1088 Rotary Autosampler is specifically designed to operate with an Aurora 1030 TOC Analyzer . The 1088 autosampler aspirates liquid samples from vials and transfers each sample aliquot to an Aurora 1030 TOC analyzer for analysis. A removable 88-position autosampler tray loads the sample vials for fully automated, unattended operation.

The 1088 supports a number of special functions to address a range of sample conditions and analysis requirements. Onboard magnetic stirring ensures samples containing insoluble components or particles are homogeneous for sampling and accurate analysis. Septum piercing provides closed vial sampling for applications where open vials may comprise the accuracy of measurements. System configuration for sample pretreatment allows pre-acidification and purging of samples within the 1088 prior to sampling. This technique removes the TIC content of samples, reducing the analysis time required for TOC measurements.

 

Specification

Dimensions (1088 Autosampler)

64.77–cm H x 38.1–cm W x 48.26–cm D

 

(25.5” H x 15” W x 19” D)

Weight (1088 Autosampler)

19 kg (42 lbs)

Dimensions

66–cm H x 47–cm W x 66–cm D

(1088 Autosampler & Aurora 1030)

(26” H x 18.5” W x 26” D)

Weight (1088 Autosampler & Aurora 1030)

34.4 kg (76 lbs)

Benchspace Footprint

3,102 cm2 (494 in2)

Environment

15–35 °C operating temperature

 

10–90% relative humidity

Sample Capacity

88 sample vials

Sampling Needle

8.4”, two-hole, stainless steel

 

Sample Transfer Tubing

0.045” I.D. x 1/8” O.D. Teflon ®

 tubing

Vials

40-mL VOA vials

 

Caps

Open-hole caps

 

Septa

TFE-faced septa

 

Sample Transfer Volume Range

10 μL–10 mL

 

Particulate Handling

Up to 500 μm

 

Special Functions

On-board magnetic stirring

 

 

Septum piercing

 

 

Sample pre-treatment for TIC removal

Power Supply

100–230 VAC (±10%); 50/60 Hz; 150 W (max)

Communication

RS-485 (Aurora 1030 analyzer to 1088 Autosampler)

Certifications

CE

Warranty

12 months on parts and labor



Download PDF Brochure

Bookmark and Share

HTML Link:

BBCode Link:

To copy the link above, just click on the input box, right click and copy

 Send to a friend Printable version Give Rate
My Rate is:

Previous:

Aurora 1030C TOC Analyzer
Aurora 1030W TOC Analyzer

Next:

Aurora 1030C (TNb) Module
1030S Solids Analysis Module
Model 1096+ XYZ TOC Autosampler
 
 
Related Categories »
 
Random »

Technical Data

PockeTester Specifications: Model pH 1 pH 2 Waterproof 5-0008 5-0010 Double Junction (pH) 5-0065 5-0067 Range -1.0 to 15.0 pH extended range Resolution 0.1 pH Accuracy ±0.2 pH ±0.1 pH Calibration Either pH 4.0, 7.0, or 10.0 Select up to 3 ... more

Back to top
Back to top

PT. PROLABMAS MURNI SWADAYA
Sentra Niaga Puri Indah Blok T3-10
Jakarta 11610 - Indonesia
Telp: +62 (21) 581 8000, 581 9000
Fax: +62 (21) 581 6999

© 2010 - 2017 Alat Lab | Alat Laboratorium
Developed by: DuaCe.com