GR150 R High performance refrigerated bath

The Grant Optima™ GR150 series of digitally controlled refrigerated baths and re-circulators provides outstanding performance for routine and sophisticated applications requiring accurate temperature control in the range of -47 to 100°C.

Grant GR150 series refrigerated systems combine the powerful and versatile Grant Optima™ digital immersion thermostat GR150 with a choice of five rugged stainless steel refrigeration units with different facilities and working volumes.

The GR150 immersion thermostat incorporates Intelligent Control Optimisation™ (ICO) for adaptive intelligent PID temperature control and includes a powerful integral pump, making GR150 series refrigerated systems suitable both for immersing samples and circulating temperature controlled fluid to external devices. The temperature range and heater power are automatically limited according to the liquid type selected.

The GR150 control unit has a host of powerful and convenient programming features for optimum application flexibility. These include a convenient heater timer for early starts/late shutdowns, a programmable relay for switching external devices on/off, option for remote temperature monitoring, RS232 interface for PC communication and data collection, and memory capacity for one program of up to 30 segments.

  • Simple-to-use rotor plus two keys provide access to the interactive interface for fast, accurate set-up
  • Dual display: bright LED for temperature display plus 2-line 16 character LCD for easy programming
  • Twin heaters, 2kW heater power for fast heat up
  • Pt1000 external probe socket for remote monitoring
  • Powerful integral pump, maximum flow 17L/min
  • Operating setpoint plus 3 adjustable preset temperatures for convenience
  • User calibration facility for optimum accuracy at the required operating temperature
  • Variable high and low temperature alarm settings - configurable to switch a relay
  • Visual and audible alarm - alert you when your attention is required
  • Choice of five operator languages
  • Choice of five refrigerated (R) tanks with different facilities, working volumes and cooling capacities
  • Cooling/heating range: -47 to 100°C (dependent on refrigeration unit selected)
  • Stability ± 0.1°C

Note: The refrigeration unit can be switched off indepedendently of the thermostat to allow heating only applications. All the refrigeration base units can be used up to a maximum temperature of 100°C.

Tank Option

The Grant Optima™ GR150 R series of refrigerated baths and re-circulators provides a choice of five models with different facilities, stainless steel tank capacities and cooling power to suit different applications.

The Grant combined tank/refrigeration units are robustly constructed for long life and efficient and reliable operation.

  • Powerful and efficient cooling with ozone friendly refrigerant
  • Rapid cool down
  • Quiet operation
  • Cooling/heating range: -47 to 100°C (in combination with GR150 thermostat; dependent on refrigerated tank selected)

Choose from the following combinations of GR150 immersion thermostat and R tank/refrigeration units:

GR150-R1

  • 5 litre tank
  • cooling power 140W @ 0°C
  • temperature range -20 to 100°C

GR150-R2

  • 5 litre tank with drain tap
  • relay control for refrigeration on/off*
  • cooling power 140W @ 0°C
  • temperature range -20 to 100°C

GR150-R3

  • 5 litre tank with drain tap
  • relay control for refrigeration on/off*
  • cooling power 156W @ 0°C
  • temperature range -30 to 100°C

GR150-R4

  • 20 litre tank with drain tap
  • refrigeration high pressure switch
  • relay control for refrigeration on/off*
  • cooling power 500W @ 0°C
  • temperature range -30 to 100°C

GR150-R5

  • 12 litre tank with drain tap
  • refrigeration high pressure switch
  • relay control fro refrigeration on/off*
  • cooling power 1050W @ 0°C
  • temperature range -47 to 100°C

Specification

   
GR150-R1
GR150-R2
GR150-R3
GR150-R4
GR150-R5
Temperature range ambient 20°C °C
-20 to 100
-20 to 100
-30 to 100
-30 to 100
-47 to 100
Pump max. pressure mbar
270
  max. flow L/min
17
Cooling power @ 20°C W
250
250
160
900
1100
  @ 0°C W
140
140
156
500
1050
Tank capacity   L
5
5
5
20
12
Drain    
no
yes
yes
yes
yes

Download PDF brochure

Bookmark and Share

HTML Link:

BBCode Link:

To copy the link above, just click on the input box, right click and copy

 Send to a friend Printable version

Previous:

GP200 R High performance refrigerated bath
Refrigeration Unit
Labwise™ software for control and analysis
Factors to consider when choosing your system…

Next:

GD100 R series Refrigerated bath
GD120 R series Refrigerated bath
 
 
 
Random »
Back to top
Back to top

PT. PROLABMAS MURNI SWADAYA
Sentra Niaga Puri Indah Blok T3-10
Jakarta 11610 - Indonesia
Telp: +62 (21) 581 8000, 581 9000
Fax: +62 (21) 581 6999

© 2010 - 2018 Alat Lab | Alat Laboratorium
Developed by: DuaCe.com